{"id":585,"date":"2012-10-19T23:14:51","date_gmt":"2012-10-19T21:14:51","guid":{"rendered":"http:\/\/tarmo.koppel.ee\/?p=585"},"modified":"2012-10-23T16:25:09","modified_gmt":"2012-10-23T14:25:09","slug":"saastelekter-arvutitookohtadel","status":"publish","type":"post","link":"https:\/\/tarmo.koppel.ee\/?p=585","title":{"rendered":"Saastelekter arvutit\u00f6\u00f6kohtadel"},"content":{"rendered":"<h6><a href=\"http:\/\/tarmo.koppel.ee\/pics\/EMD2012-logo.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-586\" title=\"EMD2012-logo\" src=\"http:\/\/tarmo.koppel.ee\/pics\/EMD2012-logo.jpg\" alt=\"\" width=\"600\" height=\"103\" srcset=\"https:\/\/tarmo.koppel.ee\/pics\/EMD2012-logo.jpg 600w, https:\/\/tarmo.koppel.ee\/pics\/EMD2012-logo-300x51.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a>K\u00e4esoleva ajaveebi autor Tarmo Koppel esitas samal teemal ettekande rahvusvahelisel teaduskonverentsil &#8220;Electromagnetic Disturbances 2012&#8221;, Vilniuses 20-21.09.12. Uurimuse kaasautor oli Jaan Niitsoo TT\u00dc Energeetikateaduskonnast. Uurimus leidis konverentsil elavat diskussiooni nii Leedu, L\u00e4ti, Iraani kui Jaapani teadlaste poolt. Autori osav\u00f5ttu konverentsist finantseeris Euroopa Sotsiaalfond SA Archimedese vahendusel.<\/h6>\n<p><strong>Saastelektriks<\/strong> (ing.k dirty electricity) loetakse elektriv\u00f5rgus ning elektriseadmetes liikuvat kesksageduslikku voolu vahemikus u 2-400kHz. Seda on v\u00f5imalik m\u00f5\u00f5ta kahel moel: 1) elektrijuhtmetes liikuva vooluna ja 2) t\u00f6\u00f6keskkonnad elektromagnetv\u00e4ljana. Tervise huvides tuleks huvi tunda eelk\u00f5ige viimase vastu, sest kui inimese keha satub elektromagnetv\u00e4lja, hakkab see, s\u00f5ltuvalt v\u00e4ljatugevusest, m\u00f5jutama ka organismi.<\/p>\n<p>Puhta, sinusoidse elektri rikuvad \u00e4ra t\u00fc\u00fcpiliselt need seadmed, mis sisaldavad kesksagedustel toimivaid komponente, n\u00e4iteks <strong>impulsstoiteadaptereid<\/strong>. Peaaegu k\u00f5ik kaasaegsed seadmed, sh energiat\u00f5husad seadmed, saavad toite sellistelt sisseehitatud v\u00f5i v\u00e4listelt adapteritelt. Kesksageduslikud adapterid tekitavad hoone elektris\u00fcsteemi (juhtmestikku) kesksageduslikku m\u00fcra ning harmoonikume. Sellega ongi loodud saastelekter. Vooluv\u00f5rgusagedus (50Hz) on kandjasignaaliks ning k\u00f5rgsageduslik v\u00f5nge &#8220;r\u00e4ndab&#8221; kaasa selle sees.<\/p>\n<h6><a href=\"http:\/\/tarmo.koppel.ee\/pics\/saastelekter-laptop.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-605\" title=\"saastelekter-laptop\" src=\"http:\/\/tarmo.koppel.ee\/pics\/saastelekter-laptop.jpg\" alt=\"\" width=\"600\" height=\"406\" srcset=\"https:\/\/tarmo.koppel.ee\/pics\/saastelekter-laptop.jpg 600w, https:\/\/tarmo.koppel.ee\/pics\/saastelekter-laptop-300x203.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a>Joonis. S\u00e4\u00e4stupirn, (impulss)toiteadapter, arvuti, plasmateler jms seadmed moonutavad majapidamise elektriv\u00f5rku kesksagedusliku m\u00fcraga. Tekib saastelekter (ing.k. dirty electricity).<\/h6>\n<p>Samas ei ole k\u00f5ik sellise koostisega seadmed ilmtingimata h\u00e4lvetega elektri tootjateks. Kasutades kvaliteetseid komponente ning lisades <strong>EMI-filtreid<\/strong> (ing.k. electromagnetic interference) on v\u00f5imalik moonutatud signaal minimeerida.<\/p>\n<p>Saastelektri allikateks v\u00f5ib pidada k\u00f5iki elektriseadmeid, kus vooluv\u00f5rgu 230V muundatakse madalamaks pingeks (n\u00e4iteks 12V madalvoolus\u00fcsteemides ja <strong>lauaarvuti toiteplokkides<\/strong>, 19V s\u00fclearvuti toiteplokkides jne). Samuti v\u00f5ib nimekirja l\u00fclitada <strong>televiisori <\/strong>(eriti plasmateler), <strong>induktsioonelektripliidid<\/strong>, l\u00e4hedalasuvad <strong>tuuleturbiinid<\/strong>, <strong>s\u00e4\u00e4stupirnid<\/strong>, <strong>p\u00e4evavalguslambid<\/strong>, <strong>arvutimonitorid<\/strong> ja kehvasti hooldatud <strong>elektriliinid<\/strong>.<\/p>\n<p>Saastelektri teema on aktuaalseks t\u00f5stnud Euroopa Liidu poliitika h\u00f5\u00f5glampide keelustamise osas, mis on <strong>s\u00e4\u00e4stupirnid<\/strong> muutnud \u00fcheks enamlevinud valgustustehnoloogiaks. Viimased on aga samuti \u00fched suuremad saastelektri allikad, mida ei uurita mitte \u00fcksnes inimese tervisem\u00f5jude osas, vaid ka elektriv\u00f5rgu toimivuse osas. Nii nagu k\u00f5ik teised voolualaldid, tekitab ka s\u00e4\u00e4stupirn vooluv\u00f5rku kesksageduslikke h\u00e4ireid (ehk saastelektrit), mis l\u00e4bi elektrijuhtmete v\u00f5ib levida \u00fcle terve majapidamise. Sellisel juhul, kui elektriseadmetes puuduvad vastavad h\u00e4irefiltrid, kumab terve elektrijuhtmestik ja kasutuses olevad elektriseadmed seda saastelektrit edasi, kiirgab seda t\u00f6\u00f6keskkonda.<\/p>\n<p>V\u00f5rreldes <strong>s\u00fclearvutite toiteadaptereid<\/strong> v\u00f5ib t\u00e4heldada suuri erinevusi saastelektri tasemetes. Kord, \u00fche arvuti puhul m\u00f5\u00f5deti nelja erinevat toiteadapterit, mis k\u00f5ik kandsid sama mudelinumbrit, kuid olid erinevate tootjate poolt: 1) originaaladapter, 2) originaaladapter \u00fcle 7a vana, 3) rikkis originaaladapter, kuid mis t\u00f6\u00f6tas, 4) hiinas j\u00e4reletehtud koopia samast adapterist.<\/p>\n<h6><a href=\"http:\/\/tarmo.koppel.ee\/pics\/power_adapter_emf.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-587\" title=\"power_adapter_emf\" src=\"http:\/\/tarmo.koppel.ee\/pics\/power_adapter_emf.jpg\" alt=\"\" width=\"400\" height=\"282\" srcset=\"https:\/\/tarmo.koppel.ee\/pics\/power_adapter_emf.jpg 400w, https:\/\/tarmo.koppel.ee\/pics\/power_adapter_emf-300x211.jpg 300w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a>Joonis. S\u00fclearvuti poolt tekitatud saastelekter on v\u00e4ikseim aku pealt toitel ja siis kui kasutatakse originaaladapterit. Vanem originaaladapter ja hiina-koopia-adapter tekitavad palju suurema saastelektri taseme. M\u00f5\u00f5detud vahemik 2-400kHz, RMS-v\u00e4\u00e4rtused.<\/h6>\n<p>J\u00e4reldada v\u00f5ib, et odav hiina adapter tekitas k\u00f5ige suurema saastelektri taseme, mis kordades suurem teistest. Samuti tekitas suure saastelektri taseme originaaladapter mis juba \u00fcle 5a vana. K\u00f5ige v\u00e4iksem saastelektri tase oli aga muidugi, kui s\u00fclearvuti t\u00f6\u00f6tas akude pealt.<\/p>\n<p>Uurimuses vaatluse all olnud k\u00fcmned arvutit\u00f6\u00f6kohad olid siiski enamus suhteliselt madala saastelektri tasemega, enamusel magnetv\u00e4li alla 50nT ja elektriv\u00e4li alla 10V\/m. T\u00f6\u00f6kohad, kus m\u00f5\u00f5deti keskmisest oluliselt k\u00f5rgemaid saastaelekter elektromagnetv\u00e4ljas kasutati l\u00e4heduses enamasti m\u00f5nda<strong> rikkis v\u00f5i kehva kvaliteediga elektriseadet<\/strong>.<\/p>\n<h6><a href=\"http:\/\/tarmo.koppel.ee\/pics\/IF-EMFs-measurements-distribution.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-589\" title=\"IF-EMFs-measurements-distribution\" src=\"http:\/\/tarmo.koppel.ee\/pics\/IF-EMFs-measurements-distribution.jpg\" alt=\"\" width=\"400\" height=\"379\" srcset=\"https:\/\/tarmo.koppel.ee\/pics\/IF-EMFs-measurements-distribution.jpg 400w, https:\/\/tarmo.koppel.ee\/pics\/IF-EMFs-measurements-distribution-300x284.jpg 300w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a>Joonis. Uurimuses m\u00f5\u00f5detud 36 t\u00f6\u00f6koha jaotus elektri- ja magnetv\u00e4lja tugevuse j\u00e4rgi. Suur osa arvutit\u00f6\u00f6kohtades langes nn rohelisse tsooni, kus saastelektri taseme oli madal. Umbes sama suur osa t\u00f6\u00f6kohti langeb kollasesse tsooni, mille saastelekter on suhteliselt madal, kuid juba v\u00f5ib t\u00e4heldada m\u00f5ne elektriseadme m\u00f5ju. M\u00f5\u00f5detud vahemik 2-400kHz, RMS-v\u00e4\u00e4rtused.<\/h6>\n<p>Elektrijuhtmetes m\u00f5\u00f5detud saastelektri tasemed n\u00e4itasid, et <strong>suuremad panustajad<\/strong> sellesse olid:<br \/>\n&#8211; rikkis lauaarvuti toiteplokk (samas oli arvuti t\u00f6\u00f6korras),<br \/>\n&#8211; infrapunal\u00fcliti valgustile (hiinas tehtud),<br \/>\n&#8211; viis s\u00e4\u00e4stupirni,<br \/>\n&#8211; t\u00f6\u00f6ruum kahek\u00fcmne lauaarvutiga,<br \/>\n&#8211; invertertehnoloogial \u00f5hksoojuspump,<br \/>\n&#8211; odav s\u00fclearvuti adapter (hiinas tehtud).<br \/>\n\u00dcks rikkis lauaarvuti toiteplokk tekitas rohkem saastelektrit kui terve toat\u00e4is (20 t\u00f6\u00f6kohta) lauaarvuteid, korras toiteplokkidega. Samas ilma elektromagnetv\u00e4lja m\u00f5\u00f5tmata ei ole v\u00f5imalik tuvastada, kas arvuti toiteplokk tekitab saastelektrit v\u00f5i mitte.<br \/>\nEsitatud nimekirja puhul ei piirdunud saastelekter vaid seadme l\u00e4heduses asuva elektripistikuga, vaid oli m\u00f5\u00f5detav \u00fcle terve t\u00f6\u00f6- v\u00f5i elamispinna.<\/p>\n<h6><a href=\"http:\/\/tarmo.koppel.ee\/pics\/CFLs-IF-EMF-upto1m-measurement.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-588\" title=\"CFLs-IF-EMF-upto1m-measurement\" src=\"http:\/\/tarmo.koppel.ee\/pics\/CFLs-IF-EMF-upto1m-measurement.jpg\" alt=\"\" width=\"600\" height=\"335\" srcset=\"https:\/\/tarmo.koppel.ee\/pics\/CFLs-IF-EMF-upto1m-measurement.jpg 600w, https:\/\/tarmo.koppel.ee\/pics\/CFLs-IF-EMF-upto1m-measurement-300x167.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a>Joonis. \u00dche s\u00e4\u00e4stupirni (CFL) saastelektri tasemed on \u00fcldisest foonist oluliselt k\u00f5rgemad kuni paari meetri peale. Halogeenpirn (230V) seejuures saastelektrit ei tekita, vaid kiirgab vahetus l\u00e4heduses edasi seda, mis juba vooluv\u00f5rgus liikumas. Joonisel m\u00f5\u00f5tmistulemused RMS-v\u00e4\u00e4rtustena.<\/h6>\n<p>M\u00f5istlik on j\u00e4rgida ELi poolt soovitatavat <strong>ettevaatlikkuse printsiipi &#8211; v\u00e4hendada elektromagnetv\u00e4lju seal kus v\u00e4hegi v\u00f5imalik ja m\u00f5istlik<\/strong>. Teadlased ei ole teadlikud veel k\u00f5ikidest v\u00f5imalikest elektromagnetv\u00e4ljade tervisem\u00f5judest, eriti kesksageduslike elektromagnetv\u00e4ljade suhtes (saastelekter) ning uurimist\u00f6\u00f6 sellel suunal veel k\u00e4ib.<\/p>\n<p>Kesksageduslikke elektromagnetv\u00e4lju (saastelektrit) on <strong>v\u00f5imalik v\u00e4hendada mitmel moel<\/strong>: minimeerides pingemuundurite (sh toiteadapterite) arvu, paigutades need inimestest eemale, vaadates \u00fcle elektrijuhtmete paigutuse, kasutates h\u00e4irefiltreid, kasutades kvaliteetseid ja mitte liiga vanu seadmeid jm. N\u00e4iteks saab saastelektri laualambist elmineerida, kui valida selline laualamp, millel pole eraldi toiteadapterit, vaid mille pirn t\u00f6\u00f6tab 230V peal. Samuti, asendades valgustites s\u00e4\u00e4stupirni halogeenpirniga (230V), on neis punktides (valgustites) saastelekter elimineeritud.<\/p>\n<h6><a href=\"http:\/\/tarmo.koppel.ee\/pics\/ext-vs-int.keyb_.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-590\" title=\"ext-vs-int.keyb\" src=\"http:\/\/tarmo.koppel.ee\/pics\/ext-vs-int.keyb_.jpg\" alt=\"\" width=\"600\" height=\"303\" srcset=\"https:\/\/tarmo.koppel.ee\/pics\/ext-vs-int.keyb_.jpg 600w, https:\/\/tarmo.koppel.ee\/pics\/ext-vs-int.keyb_-300x151.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a>Joonis. Uurimuses m\u00f5\u00f5detud kaks s\u00fclearvuti kasutamisviisi: 1) kasutades s\u00fclearvuti sisseehitatud klaviatuuri (vasakul) ja 2) kasutades v\u00e4list klaviatuuri (paremal). Saastelektrit tekitab s\u00fclearvuti oma keerulise elektroonilise skeemiga igal juhul. Samas, ekspositsiooni s\u00fclearvuti saastelektrile on v\u00f5imalik tunduvalt v\u00e4hendada, kui kasutada v\u00e4list klaviatuuri (soovitatavalt juhtmega klaviatuuri). M\u00f5\u00f5detud vahemik 2-400kHz, RMS-v\u00e4\u00e4rtused.<\/h6>\n<p>Siin kirjutises viidatud teadusartiklit v\u00f5ib k\u00fcsida e-maili teel autorilt.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>K\u00e4esoleva ajaveebi autor Tarmo Koppel esitas samal teemal ettekande rahvusvahelisel teaduskonverentsil &#8220;Electromagnetic Disturbances 2012&#8221;, Vilniuses 20-21.09.12. Uurimuse kaasautor oli Jaan Niitsoo TT\u00dc Energeetikateaduskonnast. Uurimus leidis konverentsil elavat diskussiooni nii Leedu, L\u00e4ti, Iraani kui Jaapani teadlaste poolt. Autori osav\u00f5ttu konverentsist finantseeris &hellip; <a href=\"https:\/\/tarmo.koppel.ee\/?p=585\">J\u00e4tka lugemist <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"_links":{"self":[{"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=\/wp\/v2\/posts\/585"}],"collection":[{"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=585"}],"version-history":[{"count":9,"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=\/wp\/v2\/posts\/585\/revisions"}],"predecessor-version":[{"id":592,"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=\/wp\/v2\/posts\/585\/revisions\/592"}],"wp:attachment":[{"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=585"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=585"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tarmo.koppel.ee\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}